Quantcast Testing Motor Windings

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
3.  Place  the  meter  probes  across  a  load.  You  should  obtain  a  reading. Place   one   meter   probe   on   the   right side  of  the  LLP  and  the  other  probe  on  the left   side   of   the   IT.   You   should   obtain   a reading.   If   you   obtain   no   reading,   replace   the load. To   further   increase   your   understanding   of electrical   troubleshooting,   review   the   rules you  have  just  read  using  a  different  method. The  flow  charts  in  figure  14-30(A),  and  (B) review   electrical   troubleshooting   with   a   digital multimeter.  To  use  a  multimeter  effectively and  troubleshoot  an  A/C  &  R  unit  electrically, you   must   not   only   know   the   information provided   here   but   also   practice   by   testing c i r c u i t s .    A l w a y s    r e m e m b e r    t o    r e s p e ct electricity.  Whenever  possible,  perform  your electrical   troubleshooting   with   the   power   OFF using   continuity   checks. TESTING  MOTOR  WINDINGS If,  during  the  procedure  for  identifying motor  terminals,  the  ohmmeter  displays  a blank   readout   during   any   test,   there   is probably   a   defective   winding.   A   defective winding   may   be   classified   as   an   OPEN w i n d i n g    o r    a    S H O R T E D    w i n d i n g .    T he display   will   be   zero   if   the   winding   is G R O U N D E D .    T e s t    e q u i p m e n t    a n d procedures   applicable   to   faulty   windings   are discussed   below. OPEN   WINDINGS Open  windings  can  occur  in  the  starting winding,   the   running   winding,   or   both.   An open   winding   is   the   result   of   a   burned-out   or grounded  fault  or  simply  a  break  somewhere in   the   lead   or   winding   that   prevents   the current   from   completing   the   circuit.   A   motor with  an  open  winding  does  not  start.  If  only one  winding  is  open,  the  motor  hums,  but  if both  windings  are  open,  no  sound  is  emitted nor  current  consumed.  Open  windings  can  be checked  by  an  ohmmeter,  a  voltmeter,  or  a test  light. Ohmmeter Continuity Test Procedure The  procedure  for  making  an  ohmmeter continuity   test   is   shown   in   figure   14-31   and outlined  below. Turn  the  power  OFF,  discharge  all capacitors,   and   remove   the   wires   from   the   C-, S-,  and  R-terminals  of  the  motor. With   the   ohmmeter   set   on   the   lowest scale,   check   the   resistance   from   C   to   R,   C   to S,  and  R  to  S. 14-18(E)



Construction News
 


Privacy Statement - Copyright Information. - Contact Us

comments powered by Disqus

Integrated Publishing, Inc.
9438 US Hwy 19N #311 Port Richey, FL 34668

Phone For Parts Inquiries: (727) 755-3260
Google +